Lab Anesthesia Machine
DL8Pro
EXW,FCA,FOB
1 set
300set / Week
China
7Day
Suitable for experimental animals such as rats, mice, rabbits, cats, hamsters, rats, guinea pigs, etc.
Quantity

(lab anesthesia machine)
Feature:
1.Suitable for experimental animals such as rats, mice, rabbits, cats, hamsters, rats, guinea pigs, etc.
2.Coaxial tube gas circuit design saves operating space and is easy to operate;
3.The internal serpentine pipeline design for clinical application ensures that the gas output is not affected by pressure changes;
4.Oxygen or air can be selected as gas supply source;
5.Provide accurate oxygen flow meter; flow controllable range is 0-500ml/min;
6.The anesthesia vaporizer has stable output, good airtightness, safety and reliability, and is not affected by changes in flow, temperature, flow rate, and pressure;
7.The vaporizer has automatic flow and temperature compensation, the accuracy is not lower than 0.5%, and the temperature is maintained in the range of 15-35℃, which reduces the number of dosing and makes it more convenient to use;
8.Anti-accidental opening lock structure and closed state safety protection structure to ensure safety
9.According to experimental requirements, different types and sizes of animals can choose various specifications and accessories(such as induction box,anesthesia mask ,etc);
10.Equipped with multi-channel, it can meet the anesthesia induction and maintenance experiment of 5 animals at the same time.
11.With anesthesia waste recovery system to ensure no residues and waste in the laboratory and ensure the safety of the laboratory environment;
12.One-key switch of gas path, saving time and effort;
13.With fast oxygen function, to ensure that animals inhale oxygen;
14.Can be upgraded to mobile, wall-mounted anesthesia machine;
Technical parameter:
| Gas source supply flow rate | 0.2~15L/min,If the concentration is greater than 4%,0.2~8L/min |
| Gas source supply quality requirements | Medical pure oxygen and air mixture, or O2 and N2O mixture oxygen and air |
| Channel | 1-5 optional |
| Control concentration range | Sevo 0.2-8% or Iso 0.2~5%(v/v) |
| Control knob control value | Sevo:0 - 0.2 - 0.5 - 1.0 - 1.5 - 2.0 - 2.5 - 3.0 - 3.5 - 4.0 - 4.5 -5.0-5.5-6-6.5-7-7.5-8 %(v/v) Iso:0 - 0.2 - 0.5 - 1.0 - 1.5 - 2.0 - 2.5 - 3.0 - 3.5 - 4.0 - 4.5 -5.0%(v/v) |
| Concentration control accuracy | ±5% of full scale or ±15% of set value |
| Anesthetic dose | The total volume of the dry wick is about 300mL,The visible liquid level is about 250mL between the minimum and maximum scale. |
| Consumption of anesthetic | About 3 × supply gas flow (L/min) × set concentration value (%(v/v)),When the iso concentration is 2% and the gas flow rate is adjusted to 600mL/min, a 100mL bottle of iso can be used for approximately 28-30 hours. |
| Loss of anesthetic | 22℃, 0 graduation, less than 0.5mL/24h. |
| Maximum pressure load | 20kPa |
| Maximum use tilt angle | 30° |
| Dimensions | 37 x 26 x 29 (cm) |
| Weight | about 11.5kg |
| Material | Mainly aluminum |
| Working conditions | temperature:5~40℃ Atmospheric pressure:700~1060hPa |
| Storage conditions | temperature:-40~55℃ Atmospheric pressure:500~1060hPa |

(lab anesthesia machine)


(lab anesthesia machine)









(lab anesthesia machine)






(lab anesthesia machine)
